HXP-3 training reference

Fictional light-duty plug-in hybrid training vehicle

Use the rules in this edition for the linked reference cases. General diagnostic questions include their own test conditions.

HXP-3 is a fictional series plug-in hybrid. Use these invented rules and readings for the linked practice cases.

Battery group comparison

The battery manager measures individual series-group voltages. In the guided load comparison, all groups carry the same pack current. Compare the group spread three seconds after a stable 60 A discharge begins. With pack sensors between 20 and 25 °C, the highest group minus the lowest group should be 0.15 V or less.

If the spread fails and a group repeatedly sags more than its peers, verify the sensing data and follow the group-specific diagnostic path. The comparison screens for abnormal voltage response under load. Usable capacity is assessed separately.

Battery temperature plausibility

The battery manager compares sensors T1–T4 after at least eight hours in a room with stable temperature. The traction battery must have had no charging, discharge or active heating or cooling during the soak.

Before any new heat source starts, each sensor should be within 4 °C of independently measured room temperature. An isolated outlier calls for verification of the affected sensor channel and its mounting before drawing a thermal diagnosis.

Engine requests while READY

The gasoline engine drives a generator and has no mechanical connection to the wheels. The control system can request engine operation while the vehicle is stationary in Park with READY active.

In charge-sustain mode, the battery recharge request sets below 28% state of charge and remains active until the state of charge reaches 36%. When this request clears and no other engine request is active, the engine is commanded off. READY remains active.

Front and rear power paths

The front and rear axles each have a motor, inverter and fixed reduction gear. The inverters share a high-voltage DC bus supplied by the traction battery and, when available, the engine-driven generator. There is no mechanical connection from the engine to either axle and no driveshaft linking the axles.

In the HXP-3 reduced-power mode, a rear inverter inhibit leaves rear motor torque disabled. Front drive may continue if the battery manager permits discharge and the front inverter is enabled.

Precharge decision

During startup, the return contactor closes and the current-limited precharge path raises the DC bus voltage. The main positive contactor is permitted to close once the bus reaches at least 90% of the measured pack voltage within 0.80 seconds from the precharge request.

If that criterion is not met, the controller ends precharge and withholds the main positive close command. Diagnosing a precharge timeout requires checking the precharge path and possible unintended bus load before attributing it to a contactor.

Cabin compressor permission

The electric refrigerant compressor can run while READY is active and the gasoline engine is stopped. It responds to a speed request from the climate controller after the controller checks its permission inputs.

The climate controller holds compressor speed request at zero if it marks the refrigerant pressure input invalid. The request remains zero even with maximum cabin cooling demand.

Traction-bus isolation status

The startup report separates pack-side isolation from isolation of the external DC bus. A LOW pack-side result before contactor closure directs checks to the pack-side path. A LOW external result after connection directs checks to the external path. These reports identify a diagnostic area.

Interlock and start permission

The battery manager requires a valid interlock before requesting precharge. OPEN inhibits the request. The interlock is a monitored low-voltage loop. Actual traction voltage is verified separately through the specified service procedure.

Charge and discharge limits

The battery manager reports separate limits for incoming and outgoing power. A zero charge limit suppresses regeneration and stationary charging. Positive discharge power can still permit propulsion.

Battery sensing validity

Local monitor groups M1–M4 report group voltages. A missing monitor message marks all of its values unavailable. An unavailable reading is not a measured zero. If the monitor communicates and flags one invalid channel, diagnose that input separately.

Generator request and enable

The generator inverter needs valid engine speed and an enable signal. It draws bus power to crank the engine. In generating mode the running engine drives the generator and its inverter supplies the DC bus.

Axle torque confirmation

The vehicle controller publishes the requested axle torque. Each inverter reports its received request and estimated torque. Confirm received torque before blaming the motor. An active thermal limit can intentionally reduce torque.

Inverter coolant supervision

Requested and measured pump speeds are reported separately. The controller reduces torque above 75 °C inverter coolant outlet temperature. Pump speed alone cannot verify adequate coolant flow.

AC charge permission

The inlet requires a valid pilot and confirmed latch before requesting AC charging. The charger reports AC input, enable state and delivered DC current separately. Plugged-in status can appear before the request is present.

Auxiliary converter status

The DC/DC converter reports target voltage, output current and whether current limiting is active. If output current reaches the limit while the bus falls, compare load demand and converter input conditions. The battery feed and return can be verified separately.

Braking request and deceleration

HXP-3 allows regenerative torque while the battery accepts charge and wheel-speed inputs are valid. Friction brakes provide the rest of the request. Compare actual deceleration and both contributions when diagnosing blending.

Cabin heat and coolant routing

The cabin coolant valve selects the heater core or its bypass. The controller reports both the requested and observed position. Hot inlet coolant with a bypass position during a cabin heat request directs diagnosis to valve routing.

Drive inhibit while connected

A confirmed charge connector inhibits drive even when charging current has stopped. The controller distinguishes connector presence, latch state and active charging.

Battery loop and chiller

The battery cooling loop requires coolant flow and refrigerant-side heat removal during active chiller operation. Pump-speed feedback and cooling effect are separate observations.

Onboard charger temperature protection

A separate coolant pump serves the charger. When charger temperature exceeds 72 °C, the charger lowers allowable current. The system reports station current limit and vehicle temperature limit separately.

Wheel-speed plausibility and regenerative enable

During steady straight travel the controller compares wheel-speed channels. A verified invalid channel can suspend regeneration while the allowable battery charge power remains positive.

Contactor command, coil and position evidence

The positive and return contactors each report a command, a monitored coil current and a separate position confirmation. A close command first requires a valid start permission. During the specified stationary diagnostic capture a commanded coil should draw 0.7–1.1 A once steady.

Coil current indicates electrical actuation, while the confirmation circuit indicates reported position. The training fixture can independently verify motion. A position report, command or coil reading alone does not verify absence of traction voltage.

Battery monitor addresses and group assignments

The four replaceable monitor modules are identified by address. M1 measures G1–G12, M2 G13–G24, M3 G25–G36, and M4 G37–G48. The service checker identifies an installed module address separately from its physical connector label.

A repeated or unassigned address inhibits the battery manager’s group analysis. A valid address does not verify that the physical sense connector is routed to the correct group. The prescribed service process verifies both before enabling group analysis.

Engine-generator speed relationship

The HXP-3 engine and generator are coupled by a fixed drive with a nominal generator-to-engine speed ratio of 1.50:1. During a stabilized service capture the ratio should be 1.47–1.53 when independent mechanical speed channels are valid.

The same speed ratio applies in cranking and generation. The generator inverter can report an invalid speed even when the mechanical drive remains intact. A valid mechanical ratio does not establish electrical power transfer.

Engine protection during stationary generation

During stationary generation, an engine coolant reading above 105 °C makes the engine supervisor lower allowable engine torque. The generator inverter publishes its own temperature limit separately. The training report identifies which supervisor reduced the request.

The engine and inverter use separate coolant loops. Use paired verified temperature and circulation readings when following an engine temperature limit. A valid temperature limit can reduce generation without a generator fault.

Resolver magnitude and angle checks

In the HXP-3 simulator the normalized resolver channels are S and C. The magnitude check accepts S² + C² between 0.90 and 1.10. A valid test also checks angle against a mechanical reference. At the zero marker the expected pair is S near 0 and C near +1.

At the reference marker the phase signs and mapping remain meaningful even if magnitude passes. An invalid excitation input must be resolved before the output magnitude is used to judge the resolver.

Reducer lubrication and motor coolant

Each axle has a sealed reducer with its own oil cavity. The motor and inverter coolant paths are separate from reducer oil. The reducer temperature monitor reports front and rear values independently.

The prescribed reducer comparison requires equivalent measured wheel speed, axle torque and oil starting temperature. Under those matched conditions a sustained front-to-rear difference above 18 °C calls for checking the hotter reducer’s lubrication and mechanical load. A lower difference does not certify the oil level.

Onboard charger AC input and DC delivery

The HXP-3 onboard charger converts single-phase AC from the inlet to traction-bus DC. In the stationary diagnostic capture the input comparison uses RMS voltage and current with measured power factor. The specified RMS voltage window at the charger is 200–250 V.

In the conversion comparison the onboard charger’s DC output power is calculated from measured output voltage and current. Use concurrent AC and DC measurements. A power restriction can arise before the charger or from its own temperature or control limits.

Auxiliary converter and battery current signs

The HXP-3 auxiliary current monitor uses positive current into the auxiliary battery for charging and negative current out of it for discharge. A stable voltage reading by itself does not identify the supply source.

In the training balance, converter output equals accessory load plus battery charge current, or accessory load minus battery discharge current. Use measurements from the same stabilized capture. An external support supply must be absent before applying that simple two-source balance.

Regenerated power and auxiliary consumption

In the HXP-3 steady braking worksheet, the drive inverter reports regenerated power delivered onto the DC bus. Some powers may be expressed as positive magnitudes. In this worksheet the pack’s accepted power equals bus generation minus auxiliary and other DC loads, ignoring any other losses that the case says are negligible.

The brake request separately divides mechanical deceleration between regenerative and friction torque. The battery’s charging power does not directly state the total deceleration request.

Electric cabin heater enable and output

The HXP-3 cabin heater requires a heat request, valid coolant flow feedback and a permitted power budget before its output is enabled. An enabled heater reports requested output and measured electric power separately.

At the stabilized training check, a heater drawing 2.0 kW with verified flow must raise coolant temperature at least 6 °C across the heater. Compare paired calibrated inlet and outlet readings before judging heat transfer.

Battery chiller valve routing and feedback

The HXP-3 battery valve directs flow either through the chiller or around it. The service record reports command and feedback separately, and the training fixture can independently show which branch receives flow. Chiller flow is required in active refrigerant-assisted battery cooling.

A correct command or valve position indication does not establish actual flow. For the specified check, compare chiller-branch and bypass-branch flows while the pump and cooling request remain stable.

Background sources

The fictional vehicle’s specifications are defined in this book. These sources explain the underlying systems.