L2 training reference · Version 1.0
Morrow 620 electronic diesel training reference
Fictional medium-duty electronic diesel training truck
Use the rules in this edition for the linked reference cases. General diagnostic questions include their own test conditions.
The Morrow 620 is a fictional 12 V medium-duty truck with an inline-six common rail diesel, electronically actuated variable-geometry turbocharger, and DOC, DPF and SCR aftertreatment. Each question is an independent snapshot. These values and labels are specific to this training vehicle and are unsuitable as real vehicle service specifications.
ECM power and return under starter load
The ECM battery feed passes through fuse F12 to connector C1 terminal 2. Its main return is C1 terminal 8 through ground attachment G42 to battery negative. Measure both with the ECM connected during the same cranking interval.
During cranking the battery must remain at or above 10.4 V. Maximum positive-side drop from battery positive to C1-2 is 0.30 V. Maximum return-side drop from C1-8 to battery negative is 0.15 V. The ECM requires at least 10.0 V directly across C1-2 and C1-8. A reading at C1-2 referenced to battery negative includes the voltage that can be lost on the ECM return.
Independent sensor supplies R1 and R2
The ECM supplies the rail-pressure sensor and low-side fuel pressure sensor from 5 V branch R1. It supplies the manifold pressure and oil pressure sensors from separate 5 V branch R2. Each branch should read 4.85–5.15 V to its specified sensor return with the key on and the engine off.
Use the approved key-off procedure when disconnecting a sensor. The branch wiring upstream of a disconnected sensor connector remains attached to the ECM. When the supply recovers after a sensor is disconnected, inspect that sensor and its mating connector before assigning the fault to a component.
Drivetrain J1939 termination
The ECM, transmission controller and ABS controller use one drivetrain CAN backbone. Its front and rear 120 Ω terminations are fitted to the harness ends. The two resistors are in parallel across CAN-H and CAN-L. The diagnostic breakout is on the backbone between the two ends.
With power isolated as specified, controllers disconnected and both terminators still attached, the resistance across CAN-H and CAN-L at the breakout should be 57–63 Ω. Measure each terminator separately only after removing it from the harness. A good individual terminator can still be electrically absent at the breakout if its connection to the backbone is open.
Variable-geometry turbocharger motion test
On this truck only, 0% corresponds to the most open nozzle position and 100% to the most closed position. During the stationary key-on, engine-off sweep, indicated position must settle within 5 percentage points of each request. The external position index shows nozzle travel independently of the scan reading.
If the connected sweep fails, the service procedure separates the actuator from the nozzle lever with the truck powered down and cool. Approved fixture checks assess free travel of the nozzle mechanism and actuator motion separately.
Rail pressure sensor calibration
With a valid 5.00 V reference and sensor return, the rail-pressure sensor has a nominal linear signal of 0.50 V at zero gauge pressure and 4.50 V at 200 MPa gauge. The controller interprets each 0.20 V above 0.50 V as 10 MPa. Signal tolerance at confirmed zero rail pressure is ±0.05 V.
Use the prescribed independent pressure verification before interpreting the zero-pressure check. Ignition off or the suspect scan reading alone cannot establish that the high-pressure system has safely depressurized.
SCR conversion and diesel exhaust fluid delivery
The upstream and downstream NOx sensors bracket the SCR catalyst. At the prescribed stabilized operating point, apparent conversion is 100 × (upstream NOx − downstream NOx) ÷ upstream NOx. The expected result is at least 80% when there is no regeneration, both sensors are validated and the correct diesel exhaust fluid (DEF) dose reaches the exhaust.
The approved doser capture fixture should collect 54–66 mL in its fixed-duration service test. In the same test, the delivery pressure at the doser inlet should be 500–560 kPa gauge. A pressure reading inside that range establishes inlet pressure for that test, but cannot establish the delivered volume.
Crank enable and fuel enable
The start relay command requires start request, Park or Neutral valid, and an active ignition power state. Fuel injection additionally requires valid crank and cam synchronization and a released shutdown input. A permitted crank event does not establish that fuel is enabled.
Engine speed inputs
During cranking, the ECM needs continuous crank pulses to calculate speed and a cam index to identify phase. The scan screen updates slowly. Use a simultaneous capture at sensor and ECM when pulses disappear between refreshes. A cam index fault can leave calculated speed present while synchronization remains invalid.
Gateway and separate vehicle networks
The diagnostic connector connects to the chassis segment. The gateway translates permitted engine messages from the powertrain segment. A working diagnostic connection to chassis modules can coexist with an open powertrain-side gateway branch. Verify the affected segment before replacing its modules.
Accelerator channels
The pedal contains two independently wired signal circuits. At a held position in the operating range, channel B should read half of channel A within 0.12 V. An approved test confirms reference voltage and return integrity at both sensors. With a failed correlation, the controller rejects driver torque request.
Run-relay path
When ignition is requested the ECM driver pulls the relay coil return low. Contacts feed C2-4 and must drop no more than 0.18 V under the specified load. A clicking relay confirms coil movement. Feed-voltage comparisons under load are needed to evaluate the contacts and socket.
Fan speed and feedback
The fan module accepts 5 V pulse commands from the ECM. In this training vehicle a 70% high-time request targets 1600 rpm at the specified speed and temperature. Fan speed feedback is separate from the command. Direct tachometer readings establish physical speed. The feed drop may not exceed 0.25 V under command.
Oil pressure verification
With approved oil at 95 °C, minimum true pressure is 125 kPa at 650 rpm and 250 kPa at 1600 rpm. Compare simultaneous gauge and scan readings at the specified port. A reading in range at one speed does not cancel an out-of-limit reading at another.
Coolant loop checks
Once the thermostat is commanded fully open in the training fixture, the engine outlet-to-radiator-inlet temperature difference should be 5 °C or less at the stabilized test point. The coolant outlet and inlet sensors are checked against independent probes before interpreting the difference. Fan speed and radiator airflow are checked separately.
Intake sensor comparison
With the key on, engine off, all air-path pressure taps are at ambient pressure. The BARO, manifold and pre-compressor absolute pressures must agree with the independent room reference within 3 kPa. Under load the pre-compressor reading can fall below ambient. Confirm physical pressure at the suspect tap before labeling a sensor.
Air path and cooler pressure taps
Tap P1 is the turbo outlet before the cooler; P2 is just after the cooler; P3 is at the intake manifold. At the matched airflow, maximum P1−P2 is 12 kPa and maximum P2−P3 is 4 kPa. A separate static leak test checks loss of air through joints and tanks. Pressure comparisons at unequal airflow are invalid.
Boost control dependencies
Torque request, barometric pressure and coolant protection feed the boost target calculation. At the stabilized case condition, measured manifold pressure within 7 kPa of the calculated target satisfies boost control. Reduced target due to protection is evaluated before treating low absolute boost as turbo failure.
EGR position and measured flow
At the prescribed stabilized test point, a commanded opening moves the valve from 5% to 40%. Correct position feedback should be within 4 points of command. With other conditions held fixed, fresh-air flow should fall by at least 15 g/s. A normal position trace does not establish gas flow through the passage.
Low-pressure fuel path
Pressure taps F1 and F2 bracket the secondary filter. At the matched service flow, the F1−F2 pressure loss must be 35 kPa or less and F2 must be at least 260 kPa gauge. Pump outlet F1 is not the inlet pressure at the high-pressure pump. A normal filter drop with low readings on both sides directs diagnosis upstream.
Commanded rail pressure
At the authorized cranking comparison, target rail pressure is 35 MPa and injection requires at least 30 MPa along with valid synchronization. During the stabilized loaded comparison, actual must remain within 8 MPa of requested. Check low feed, independent pressure and approved internal leakage measurements before condemning high-pressure hardware.
Matched return capture
The fixed-duration hot cranking capture compares individual return volumes. At the stated conditions, each injector may return up to 12 mL and the largest-to-smallest difference must not exceed 6 mL. The manifold return includes the rail limiter and is not an injector-only measurement.
Fuel temperature sensor
The fuel sensor is a thermistor in an ECM pull-up circuit. At the matched comparison temperatures, 20 °C corresponds to 3.1 V, 40 °C to 2.2 V and 60 °C to 1.4 V. The healthy circuit allows ±0.10 V at the fixed points. An open circuit produces voltage near the 5 V pull-up.
Rail limiter return
The limiter return has its own outlet. During the approved cranking capture it should collect at most 2 mL in ten seconds, separate from injector returns. A failed-open limiter can return fuel at low rail pressure. The pressure test uses only rated equipment and independent verified depressurization where required.
DPF pressure and flow
The differential sensor reads pressure immediately upstream minus immediately downstream of the filter. With both taps at the same known pressure, zero must be within ±0.4 kPa. At the stated matched exhaust flow, the measured physical differential should be 8 kPa or less after verified soot removal. Use a separate instrument to distinguish sensor error from restriction.
Stationary regeneration permissions
Stationary regeneration is permitted only when coolant is at least 75 °C, fuel is at least 20%, the parking input is applied, and soot is no more than 95%. The diagnostic screen reports each permission separately. If soot exceeds 95%, stop the stationary routine and follow the approved high-soot service path.
Oxidation catalyst temperature rise
At the specified stable diagnostic condition, commanded hydrocarbon dosing must be verified. With the inlet at least 245 °C, an active DOC should increase the outlet temperature by at least 35 °C during this training test. Independent temperature validation and doser delivery checks precede a catalyst conclusion.
NOx comparison and sensor identity
The two NOx sensor modules use assigned addresses for positions before and after the SCR catalyst. The test screen labels readings by address. The harness and scan identities must match physical location before applying the conversion calculation. Two plausible readings can be assigned to the wrong positions.
DEF condition and dosing
The approved concentration range is 31.8–33.2% urea by mass. An instrument check is required before using the reading. A concentration pass does not establish chemical purity. In the authorized thaw test, solution temperature must reach at least 4 °C before the dosing enable may change from inhibited to available.
Retarder command permissions
The engine brake command requires switch enabled, pedal request below 2%, cruise not requesting drive torque, and clutch engaged. A vehicle speed condition is verified separately. A denied command is diagnosed from inputs before testing the retarder actuator.
First-event shutdown log
The training ECM stores a timestamped protection event with its input, threshold and mode. The first qualifying event causes the shutdown request. Later voltage and speed changes can reflect the engine stopping. Diagnose the first independently verified threshold event, then confirm repair under comparable conditions.
Background sources
The fictional vehicle’s specifications are defined in this book. These sources explain the underlying systems.
- ASE L2 Study Guide, test specifications and task list
- International J1939 backbone checks, including the 57–63 Ω range (steps 11–21)
- International service information on testing VGT movement
- Garrett turbocharger system diagnostics
- Bosch common rail pressure sensing and control
- Caterpillar reference on the high-pressure oil supply for HEUI
- Cummins aftertreatment fundamentals
- API guidance on diesel exhaust fluid quality and concentration