A6 study guide
How to do a voltage drop test
Find hidden resistance in cables, grounds and connections by measuring the circuit while it works.
Key points
- Measure voltage drop only while the circuit is loaded and working.
- Test the positive side and the ground side separately, then narrow down by moving one lead.
- An ohmmeter can miss resistance that shows up under high current.
What a voltage drop test proves
Every wire, terminal and switch in a circuit has a little resistance. When current flows through that resistance, some voltage is used up before it reaches the load. A voltage drop test measures exactly how much is lost across one section of the circuit, so you can find a corroded terminal or undersized ground without taking anything apart.
An ohmmeter is a poor tool for this job. It pushes a tiny current through the wire, and a cable with three strands left intact will read almost zero ohms. Put 150 amps of starter current through those same three strands and they turn into a heater. The voltage drop test catches that, because it measures the circuit at working current.
The rule that makes it work: the circuit must be on
Voltage drop only exists while current flows. With the key off, a badly corroded battery cable shows 0.00 volts across it, the same as a perfect one. Crank the engine, turn on the headlights or run the blower before you read the meter. If you are testing a circuit that will not turn on, you are not doing a voltage drop test yet. Start with available voltage and continuity instead.
Set the meter to DC volts. Most cables and grounds should read well under one volt, so a meter that auto-ranges into the millivolt scale makes small losses easier to see.
Testing a starter circuit step by step
- Disable fuel or ignition so the engine cranks without starting, and confirm the battery is charged. A weak battery lowers cranking current and hides resistance.
- Positive side: place the red lead on the battery positive post itself, not the cable clamp, and the black lead on the starter’s battery terminal. Crank and read the meter.
- Ground side: place the red lead on the starter housing or engine block and the black lead on the battery negative post. Crank and read the meter.
- If either side is high, move one lead in steps toward the other: post to clamp, clamp to cable end, cable end to terminal. The reading jumps across the bad connection.
- Repair the connection, then repeat the test. The fix is only proven when the drop is back within the limit under load.
How much drop is too much?
Manufacturers publish their own limits, and you should use those when you have them. Without them, technicians commonly work from rules of thumb like the ones below. Treat them as a starting point, not a specification.
| Section of circuit | Common rule of thumb |
|---|---|
| A single clean connection | About 0.1 V or less |
| Starter positive cable, post to starter | About 0.5 V or less while cranking |
| Engine ground, block to battery negative | About 0.2 to 0.3 V or less while cranking |
| Charging output wire, generator to battery | About 0.2 to 0.5 V or less at high output |
| Low-current lighting or sensor circuits | Much smaller, often tens of millivolts |
Charging and lighting circuits
The same method finds charging problems that look like a bad generator. Load the system with headlights, blower and rear defrost at a fast idle, then measure from the generator output terminal to the battery positive post, and from the generator case to the battery negative post. A high reading on either side means the battery never sees the voltage the generator is making, and the battery can stay undercharged with a good generator.
On a dim headlamp, measure across the switch, across the connector at the bulb, and from the lamp ground to battery negative with the lights on. Whichever section uses up the voltage is the section with the fault.
How voltage drop shows up on ASE A6 questions
- A slow-cranking engine with a good battery and a high reading across the ground side: the answer is the ground connection or cable, not the starter.
- Meter leads placed across a closed switch read nearly zero when the switch is good. A reading close to battery voltage across a switch means it is open.
- Questions often offer an ohmmeter check as a distractor. When the circuit carries high current, the loaded voltage drop test is the better next step.
- Watch which side the leads are on. A reading taken from battery positive to the starter terminal tests the feed side only.
Common questions
- Why does a voltage drop test need the circuit turned on?
- Voltage is only lost across resistance while current is flowing. With no current, a corroded connection and a clean one both read zero volts, so the test cannot see the fault.
- What is an acceptable voltage drop on a battery cable?
- Use the manufacturer’s figure when it is available. A common rule of thumb is about half a volt or less on the starter positive cable while cranking, and less than that on the ground side.
- Can I use an ohmmeter instead of a voltage drop test?
- Not reliably on high-current circuits. An ohmmeter uses a very small current, so a cable with only a few good strands can still read nearly zero ohms while failing under load.
General training, not a repair procedure. Follow the manufacturer’s service information and specifications on a real vehicle. ASE Practice is independent and not affiliated with ASE.