A7 training
Heating & Air Conditioning
Decide whether the complaint is temperature or airflow, then follow the refrigerant and the cabin air.
Refrigerant moves heat by changing state
The compressor raises the pressure and temperature of refrigerant vapor. In the condenser that vapor gives up heat to outside air and condenses into a liquid. The expansion device, either a thermal expansion valve or an orifice tube, drops the pressure. In the evaporator the low-pressure liquid boils and absorbs heat from the cabin air, then returns to the compressor as a vapor.
The high side runs from the compressor outlet to the expansion device; the low side runs from the expansion device back to the compressor. Expansion valve systems use a receiver-drier on the high side, and orifice tube systems use an accumulator on the low side.
Read gauge pressures against the conditions
Pressures depend on ambient temperature, humidity, engine speed and airflow, so compare them with the chart for the conditions in the question. Both sides low points to an undercharge. Both sides high can mean an overcharge or poor airflow across the condenser, so check the cooling fan first. A very low low side with a temperature drop or frost at one point suggests a restriction there.
No heat or wrong vent is an air or coolant problem
For a heating complaint, check coolant level and whether both heater hoses are hot. Low coolant can cause poor heat at idle that improves with engine speed. For air coming out of the wrong outlet or at the wrong temperature, look at the blend and mode doors and their actuators.
Traps that cost points
- Adding refrigerant before checking for a condenser airflow problem.
- Reading pressures without regard to ambient temperature.
- Treating an air-distribution complaint as a refrigerant problem.