A7 study guide
A/C refrigerant leak detection
Find the leak before you charge, using the right tool for the size and place of the leak.
Key points
- Find and fix the leak before charging the system.
- Move an electronic detector slowly and check below fittings.
- Check the evaporator at the condensate drain.
Find it before you fill it
A system that is low on refrigerant has a leak. Recharging without finding it means the customer comes back, refrigerant goes into the air, and the compressor may run short of oil. Most leak checks need some pressure in the system, so check the static pressure first and add a small amount of refrigerant if the system is nearly empty and the procedure allows it.
Choosing the method
| Method | Best for | Watch out for |
|---|---|---|
| Electronic leak detector | Small leaks anywhere you can reach with the probe | Move the probe slowly, about 1 inch per second, below fittings; wind and engine heat spread the sample |
| UV dye and lamp | Finding leaks over time and in hard-to-see places | Use only the dye and amount the manufacturer approves; old dye from a past leak can mislead |
| Bubble solution | Confirming a suspected leak at a fitting or valve | Too slow to search a whole system |
| Nitrogen pressure test | An empty system, or proving a repair holds | Use a regulator and stay within the specified pressure |
| Vacuum decay | Confirming the system is sealed before charging | A vacuum test does not reproduce operating pressure |
Where leaks usually are
Refrigerant is heavier than air, so check below a suspected spot. Oily residue at a fitting is a strong clue, because refrigerant oil travels with leaking refrigerant.
- Service port valve cores and missing caps.
- O-rings at hose and line connections.
- The compressor shaft seal, often shown by oil spray around the clutch.
- The condenser, which is exposed to stones and road debris.
- The evaporator, inside the case and hard to reach.
Checking the evaporator
Because the evaporator sits inside the heater and A/C case, test it at the condensate drain tube or at a vent with the blower off and the system at rest. If you added UV dye, look for dye at the drain. Some technicians remove a blower resistor or cabin filter to get the probe closer.
How leak detection shows up on ASE A7 questions
- The electronic detector probe should move slowly and below fittings, because refrigerant is heavier than air.
- Oil residue at a connection points to a refrigerant leak there.
- An evaporator leak is checked at the condensate drain.
- The correct step after finding a low charge is leak testing, not just recharging.
Common questions
- What is the best way to find an A/C leak?
- Use an electronic leak detector for a quick search, UV dye for hard-to-reach or slow leaks, and bubble solution to confirm a suspected spot. An empty system can be pressure tested with nitrogen.
- How do you check for an evaporator leak?
- With the system at rest and the blower off, place the electronic detector probe at the condensate drain tube, or look for UV dye there if dye was added.
- Why check below fittings for refrigerant leaks?
- Refrigerant is heavier than air, so it sinks after leaving a fitting. Moving the detector probe slowly beneath connections catches it.
General training, not a repair procedure. Follow the manufacturer’s service information and specifications on a real vehicle. ASE Practice is independent and not affiliated with ASE.